11kv 2 pole structure drawing

FITTINGS ON TERMINAL SECTION T-OFF POLES. 6611 kV outdoor substation Single line diagram.


Two Pole Mounted Transformer Substation 65 04 Kb Bibliocad

6 8 9 10 11 and 13 Mtr.

. The all four terminals incuding neutral comes from secondary of PT. Fig i shows the layout of pole-mounted sub-station 2. As it does not involve any building work.

Single Core Under Ground Cable. A4-566092 for standard 3 4 5 9 300 6 hv earth 3600 to first pole step 1 230 existing hv mains new fuse hv supply to capacitor bank a a a n construction detail modification to edo pole 18 10 abc pole termination install new lv abc from this pole to. Standard Drawing for laying of 11 KV 3 Nos.

4213 The composite line post insulators shall have a core an insulating housing and weather-shed housing both manufactured by the same manufacturer and a stainless steel hardware components for attaching it to the support and conductor. Whereas Fig ii shows the schematic connections. And shall not be out of straight by more than one thousandth of the length of the pole.

Standard Drawing for Earth Rod 20 mm dia M. Power lines and double pole structures for 1104 KV substations. The 11 kV line is connected to the transformer 11kV 400 V through gang isolator and fuses.

LINE CONFIGURATION UPCLLT01 45 POSITION OF LT. 25 FOR 11 KV AND LT LINES 1. SlNo Drawing Description Drawing Number.

MV cable LV cable Fig shows the single line diagram of 11KVV substation DP structure. Standard Drawing for supporting Structure for 33 KV Lighting. 13000 Structure.

OVERHEAD LINES FOR ROAD CROSSING UPCL11KV19 44 LT. Such an arrangement of two incoming lines is called a. This Specification covers PCC poles with an overall length of 75 M 80 M and 90 M suitable for use in overhead 11 KV and LT.

A Transmission Line Standards Steel Pole Structures. SETS Without Support AGAINST TN-1090 1. Standard Drawing for 11 KV Line V-Cross Arm for Use where Conductor of 50 mm2 or below is proposed.

Power lines and double pole structures for 1104 KV substations. Power lines and double pole structures for 1104 KV substations. PRESTRESSED CEMENT CONCRETE POLES FOS.

TECHNICAL SPECIFICATION FOR SUPPLY OF 1104 KV SS DOUBLE POLE STRUCTURE 11 KV LINE DP. Rigidly on a supporting structure by means of a central stud or one or more bolts as per IEC 60815-3. Application Standard for PCC Pole.

Connecting all outgoing Feeders up to pole Including 14250 m of 3150mm2 cable pole with acssesories BC1 BR1 Metering p1 Capacitor 1 Outgoing F1 Outgoing F2 F3 INCOME 1 F4 F5 F6 F7 C 2 Aux2 F8 F9 F10 INC2 F11 F12 F13 F14 U N D P 3311 kV Substations 2315 MVA 33 KV 3Pos. Type 2 Tubular Steel Pole. 2-1 or 2-11 construction ground line ground line 8 2 11 11kv hv dolf construction refer drg.

162475_01 645kb STANDARD CONSTRUCTION 11KV POLE TOP CAPACITORS CONSTRUCTION DETAIL. They refer to the top of the main pole structure. Mild Steel Hot-Dip Galvanized.

IBEAM 150X75 175X85 200X100 116X100 152X152 MM. 1678-1978 Specification for pre stressed concrete poles for overhead power traction and telecommunication lines. Its has three terminals for Voltages RYB and one for neutral.

The transformer and other equipment are mounted on H-type pole or 4-pole structure. 42 GENERAL ARRANGEMENT OF DISTRIBUTION TRANSFORMER ON SP-55 DOUBLE POLE STRUCTURE UPCL11KV18 43 GUARDING BELOW 11 KV. Figure 1 shows the single-line diagram of a typical 6611 kV substation.

DS 1250 A 25 KA3s 33 KV. The single line diagram contains the Fig Layout and Single Line Diagram Of Pole Mounted Distribution Substation. Substation provides the energy supply for the local area in which the line is located.

Hardware Set 1 14500 14500 30900 10 1305000001 11 KV H G FusesPolymeric No 3 84600 253800 11 KV DOUBLE POLE STRUCTURE AT SS END FOR OH LINE and UG CABLE USING. The main function of the substation is to receive the energy transmitted at high voltage from the generating station and then reduce the voltage to an appropriate value for local. 215 Providing and fixing in position of 11KV LA Set Station Type 20 set 216 Providing and fixing in position of 11 kV Disc Insulators polymerporcelain Completewith fitting45KN 70 no 217 Providing and fixing in position of 11 KV Pin Insulators polymerporcelain with Pins5KN 70.

A Transmission Line Standards Steel Pole Structures Aerial Patrol Mile M arker and Number Signs Sh. Application Standard for PCC Pole. 162475_02 480kb STANDARD CONSTRUCTION 11KV POLE TOP CAPACITORS MODIFICATION TO EDO CONSTRUCTION DETAIL.

Some designs achieve minimum EMF emission by installing the low voltage cables and switchboard in a trench down the middle of the room. This Specification covers PCC poles with an overall length of 75 M 80 M and 90 M suitable for use in overhead 11 KV and LT. 2001000005 a 11 KV Disc.

25000 PIECE Get Latest Price. B Standard Designs Transmission Lines Type 3TA-1 69 and 115kV 3-Pole Tension Structure. CONSTRUCTION STANDARD DRAWINGS DIVISION 15.

514373_01 151kb STANDARD CONSTRUCTION 2700mm CROSSARMS FOR LV 11KV 22KV AND 33KV. The following layout designs of indoor distribution substation are typical only and should not be used as construction drawings as they are presented as an example. 11kV Indoor distribution substation.

11kV overhead lines with maximum conductor size 12020 ACSR and LV lines with. SCOPE This specification covers fabrication testing delivery of fabricated steel items as a complete package complete in all respect as per GTPDrawings to be provided by the purchaser to the successful bidder. Three Phase Prefab Double Pole Structure.

1 of 3 126. Lets explain the main parts of it and how it actually works. 9 11 KV STRAIN INSULATORS WITH SET 6 30900 185400 HW OF PREFORMED FITTING.

There are two 66 kV incoming lines marked incoming 1 and incoming 2 connected to the bus-bars. Insulator Polymeric No 1 16400 16400 2010000077 b 11KV Disc. 11 KV Double Pole Structure.

CONFIGURATION 21 Lines The transmission lines shall be routed to avoid length of parallelism between power and Communication circuits as far as possible. Call 08048372852 Ext 826. Type 1 Tubular Steel Pole cw Accessories.

11 kV SIDE IS AIR INSULATED SWITCHGEAR. 1678-1978 Specification for pre stressed concrete poles for overhead power traction and telecommunication lines. Minimum separation distance between power and Communication Circuits should be kept as 61 metres 200 ft for 33 KV line provided length of parallelism does not exceed 16 Km.

This Specification covers PCC poles with an overall length of 75 M 80 M and 90 M suitable for use in overhead 11 KV and LT. The single line diagram makes the system easy and it provides the facilitates reading of the electrical supply.


Three Phase Two Pole Structure Installation Rs 180000 Unit Yash Electrotech Id 23035074897


11 Kv Double Pole Structure At Rs 70000 Unit डबल प ल स ट रक चर Mars Electrical Works Chennai Id 20793590755


Mv Three Phase H Pole Transformer Structure 11kv And 33kv Thousands Of Free Autocad Drawings


Drawings For Steel Tubular Poles Bhutan Power Corporation Limited


Electrical Ideas Dtr Structure Dp Structure Double Pole Structure Facebook


Installation And Commissioning Of 11 0 43 Kv Substation Eep


11 Kv Line Dp 11 Kv Double Pole Youtube


Single Line Diagram Of Pole Mounted Substation L 11kv 415 V Substation Youtube

0 comments

Post a Comment